Abstrak – Kota Ternate merupakan pusat pengembangan masyarakat dimana seiring berjalannya waktu semakin banyak pembangunan gedung dan lainnya sehingga mengakibatkan meningkatnya kebutuhan energi listrik di kota Ternate. Ketersediaan energi listrik di kota Ternate harus dapat memenuhi kebutuhan seluruh konsumen, dan energi listrik harus dapat digunakan secara optimal oleh pelanggan agar tidak mengalami penyusutan energi dalam sistem jaringan listrik mulai dari pembangkit sampai ke konsumen. Beban listrik dikota Ternte melebihi standart SPLN yang disediakan yaitu 10%. Untuk itu harus dilakukan perbaikan kualitas tegangan di kota Ternate.Beberapa penyulang dikota Ternate memiliki jatuh tegangan yang melebihi standar SPLN maka dilakukan perbaikan kualitas tegangan. Perbaikan kualitas tegangan dengan menggunakan metode kapasitor bank menghasilkan nilai jatuh tegangan pada penyulang-penyulang yang melebihi standar menjadi sesuai standar yaitu 10%. Kata kunci : Kapasitor Bank, Kualitas tegangan, Jatuh tegangan. Abstract – Ternate City is the center of community development where over time more and more buildings and other developments have resulted in increasing demand for electrical energy in the city of Ternate. The availability of electrical energy in the city of Ternate must be able to meet the needs of all consumers, and electrical energy must be used optimally by customers so as not to experience energy depreciation in the power grid system from generators to consumers. The electricity load in the city of Ternte exceeds the standard SPLN provided, which is 10%. Therefore, it is necessary to improve the stress quality in the city of Ternate. Some of the feeders in the city of Ternate have a stress drop that exceeds the SPLN standard so that the stress quality is improved. Improving the quality of the voltage using the capacitor bank method resulted in a voltage drop in the feeders that exceeded the standard to be according to the standard, namely 10%. Keywords: Capacitor Bank, Voltage Quality, Voltage Drop

Item Type: Other
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: UNSPECIFIED
Depositing User: Mr. Benhard W. Tampangela, ST
Date Deposited: 01 Mar 2021 05:47
Last Modified: 01 Mar 2021 05:47
URI: http://repo.unsrat.ac.id/id/eprint/3053

Actions (login required)

View Item View Item